Reports 1-1 of 1 Clear search Modify search
VIS (EX)
kunihiko.hasegawa - 12:26 Wednesday 06 June 2018 (5187) Print this report
ETMX TypeA suspension helth check

[Miyamoto (from his home), Hasegawa]
The other day, Miyamoto san found the behavior of ETMX suspension strange. (related report : 5109  :5175)
In order to modify the problems,  TypeA suspension was checked. (5184)

Today, we measured Transfer Function (TF) of each stage (F0,F1,F2,F3,BF) to know the current condition of the suspension.
The results were attached or you can find these results in
/users/VISsvn/TypeAtower/ETMX/TF/20180606/

As you can find in results, all of TFs seem comparable with previous measurement by Okutomi san (you can find hereEXCEPT F0 result.
We are thinking that still TypeA suspension has something wrong and F0 should be modified.

After above modification, we will evaluate the TF inculde the cryogenic payload again.

Images attached to this report
Comments to this report:
kiwamu.izumi - 13:28 Wednesday 06 June 2018 (5188) Print this report

Hey Hasagawa-kun,

Thank you for the concise report. It is sad to hear that F0 is still not in a good shape. By the way, the attached screenshot is the package of F-zero for super Nintendo.

Images attached to this comment
takahiro.miyamoto - 0:13 Thursday 07 June 2018 (5202) Print this report

attached the power spectrum graph of 2018/05/29 and 2018/06/06

maybe imporving.

just log

Images attached to this comment