Reports 1-1 of 1 Clear search Modify search
VIS (EX)
ryutaro.takahashi - 21:15 Tuesday 05 June 2018 (5184) Print this report
Alignment of BF
[Takahashi, Sato, Shimizu + Tomaru]

Status:
- The horizontal primary coil of BF damper was touching the secondary coil. The BF was rotated to the CCW in yaw.
- The height of keystone in the TF was not changed (5.5mm).
- The F1 damper was touching the Cu plate.

Adjustment:
- The height of F1 damper was increased by 6mm.
- The yaw position of BF damper was adjusted by the yaw screw in the TF.
- The cryo-payload was aligned by the yaw picomotor in the BF.