Reports 1-1 of 1 Clear search Modify search
VIS (IX)
ryutaro.takahashi - 18:01 Friday 09 March 2018 (4406) Print this report
Setting of F2
[Takahashi, Sato]

1) Adjusted the LVDT driver channel for F2.
2) Calibrated the LVDT in F2. The first measurement was indicated by red .
3) Shifted down the secondary coil by 3mm.
4) Calibrated again. The curve was shifted to blue.

* The LVDT driver was driven by not +/- 18V but +/- 10V due to temporal power supply.
This calibration should be done again later.
Images attached to this report
Search Help
×