[Akutsu, Simon, Kokeyama]
Since there are some mistakes on IMMT1/2 oplevs (listed below), we fixed them and re-installed.
OL transmitter (TX) and receiver (RX)
- The heights of the TXs were lower. Two pedestal spacers (6.35mm, 3.3mm) were added to the regular 50.8mm pedestals.
- The square spacer on the receiver (RX, DCQPD) was wrong: ones for the length sensing oplev was used. We replaced them to the regular spacer.
- The AC cable for the light source of IMMT1 OL was replaced to the proper one
- The driver boxes of the light sources were fixed properly
- The fibers were cleaned by the fiber cleaner tool
IMMT2 OL folding mirror
- The large pedestal was swapped to the default one (185mm, alpica coated) from the one by Somiya-lab (175mm, bare)
- The folding mirror was swapped to the proper one. So far we were using temporary IR mirror.
- They were not aligned. To be done when IMMT2 is fixed.