masayuki.nakano - 17:48 Thursday 07 September 2017 (3345) Print this report
Align the IMC

The IMC is aligned. In last one month the IMC TRANS signal has  dicreased and actually the alignment was bad in pitch direction.
Now the TRANS signal seems good.

I tried to check the oplev signals of each suspensions but the data was empty in 20days;(


 

Images attached to this report
Comments to this report:
keiko.kokeyama - 19:05 Thursday 07 September 2017 (3348) Print this report

Recently trend writing function is not working properly. But  "second trend" is working and you can try it.