Reports 1-1 of 1 Clear search Modify search
AOS (Beam Reducing Telescopes)
satoshi.tanioka - 22:30 Wednesday 24 May 2017 (2803) Print this report
Coil winding

at Mitaka

I wound a wire on a coil for an actuator in 4 layers.
Wire size was 32 AWG.
This coil was designed to turn 182 times per layer, but it was less than 182 times.
The direction of winding is opposite to the design because of winding machine problem.

It became difficult to distinguish the wire from the lower layer in the second and subsequent layers.
I put a Kapton tape to distinguish different layers.

I am not used to winding and it took long time...
Images attached to this report
Comments to this report:
satoshi.tanioka - 22:33 Monday 29 May 2017 (2820) Print this report

[at Mitaka]
I measured the coil properties at 120kHz. The results are shown as below.

Resistance: 121Ω
Inductance: 47mH
Q factor: 286
satoshi.tanioka - 10:20 Tuesday 30 May 2017 (2821) Print this report
120kHz -> 120Hz
satoshi.tanioka - 13:57 Tuesday 30 May 2017 (2823) Print this report
Q factor: 286 -> 0.286
I apologize for frequently correction.
Search Help
×

Warning

×