koki.okutomi - 18:46 Tuesday 14 February 2017 (2482) Print this report
Tuning of BF GAS and connector assembling

[Takahashi, Sato, Okutomi]

Tuning of optimal weight for BF GAS

  • We tuned weight of the Dummy Payload (DP) to the optimal one for BF GAS

   Optimal weight [kg]          Resonant freq. [Hz]          Height of keystone [mm]
  -------------------------------------------------------------------------------------------------------
       202.78 +/- 0.1                        0.397                                     67.5

(cf. BF optimal weight measurement in Mitaka: JGW-T1605099)

  • We loaded flanges, shackles and other stuffs on the DP for temporary use
    • We'll bring some suitable weights from Mitaka for immediate necessity to continue the installation work (maybe in next week)
    • Anyway we have to procure additional masses

Cabling and connector assembling

  • We are on the way of making connectors for GAS LVDT, stepper motors and picomotors
  • Setup of the driver circuits around the DGS rack is also ongoing in parallel

Photos >>> https://goo.gl/photos/4XEcycdvNXjY9tyv9