takafumi.ushiba - 15:23 Sunday 11 July 2021 (17472) Print this report
Comment to MNH1 actuator of ITMX seems to have an issue. (17468)

I found the healthy TF in klog17158, which is measured on 18 of June.
So, this actuator efficiency drop must be occurred between 18 of June and 2 of July.

According to the klog, there is a work for repairing the BF actuator cables.