Implemented some Oplev-related fixes to the VIS model file.

Corrected VIS model file.

  • Connected MN OpLev output to ADD (request from Ushiba-san)
  • Connected TM OpLev to BF's ADD (requested by Miyo-san).
  • Remove the IP OpLev input (unused) (Request from Miyo-san)

[Details]

  • Connects output of MN OpLev to ADD.

 Added K1:VIS-{optic}_MN_MNOLDAMP_{L,T,V,R,P,Y}.
 optic=ETMX,ETMY,ITMX,ITMY

 PAYLOAD_MASTER:
 Added DAQ Channels
 K1:VIS-{optic}_MN_MNOLDAMP_{L,T,V,R,P,Y}_IN 1024
 K1:VIS-{optic}_MN_MNOLDAMP_{L,T,V,R,P,Y}_OUT 256
 optic: ETMX,ETMY,ITMX,ITMY

  • Connected TM OpLev to BF's ADD

 PAYLOAD_MASTER:
  Output from TM to TOP and store in SHMEM
  The name of SHMEM is
  K1:VIS-{optic}P_TM_OPLEV_{L,P,Y}_OUT
  optic: ETMX, ETMY, ITMX, ITMY, BS, SR2, SR3, PRM, PR2, PR3 (except SRM)

 TOWER_MASTER:
  Add OPLEV to BF from SHSMEM of TM's OPLEV stored in PAYLOAD, and input its output to ADD.
 K1:Add VIS-{optic}_BF_OLDAMP_{L,P,Y}

 Added DAQ Channels
  K1:VIS-{optic}_BF_OLDAMP_{L,P,Y}_IN 1024
  K1:VIS-{optic}_BF_OLDAMP_{L,P,Y}_OUT 256
  optic: ETMX, ETMY, ITMX, ITMY, BS, SR2, SR3, PRM, PR2, PR3 (except SRM)

  • Remove the IP OpLev input (not used).

  TOWER_MASTER:
  Delete TM_OPLEV_{L,Y} and IP_TMOLDAMP.

  • In addition to the above, the placement of the TOP of each model has been unified

GitID: release/0.1.15