With Hirata-san.
See pictures in album PR3 Remedying Work.
Becuase we had used a broken laser level set the pitch of the mirror, we repeated the measurement with a different laser level know to work fine.
- A new measurement showed thre pitch was -6.1 mrad.
- We corrected it with the picomotor setting it at -3.3 mrad.
- Using the fishing rod we moved the keystone close to the setpoint.
- Two of the vertical OSEMs became out of range. We need to correct them.