[Takahashi, Sato, Horiuchi, Miyo(remote)]
- Calibrated the LVDT in BF again. Blue line in the plot #4 shows new measurement.
- Measured the TF without the cup. The resonant frequency was ~0.35Hz.
- Closed the cup. Then the keystone went down.
- Removed some ballast weight (440g x 3 + 60g = 1380g).
- Measured the TF with the cup. The resonant frequency was ~0.2Hz.
- Hung the F3 by the crane. Then the keystone went down.
- Removed some ballast weight (86g + 44g + 62g = 192g)
- Measured the TF with the cup hung. The resonant frequency was ~0.2Hz.