Reports 1-1 of 1 Clear search Modify search
VIS (IX)
satoru.ikeda - 11:53 Tuesday 22 December 2020 (15675) Print this report
Support for common Payload model files: Payload of Type-A (ITMX) is supported to PAYLOAD_MASTER.

Model commonization: Type-A(ITMX) to PAYLOAD_MASTER

k1visitmxp:
Model:

 Change to a model that uses PAYLOAD_MASTER/CRYO_PAYLOAD_MASTER as well as ETMY and ETMX.

  •  Remove the following SHMEM

 K1:VIS-ITMX_MN_COIL_{V1,V2,V3,H1,H2,H3}
 K1:VIS-ITMX_IM_COIL_{V1,V2,V3,H1,H2,H3}
 K1:VIS-ITMX_TM_COIL_{H1,H2,H3}
 K1:MODALITMX_OL{L,P,Y}
 K1:VISITMXP-VISITMXT_COM2{L,Y}
 Add the following SHMEM
 K1:VIS-ITMXP_ISC_MN_OUT

Foton:

 Remove all MOD_*.
 MOD_ITMX_AI_IM_{LEN,PIT,ROL,TRA,VER,YAW}
 MOD_ITMX_AI_MN_{LEN,PIT,ROL,TRA,VER,YAW}
 MOD_ITMX_AI_TM_{LEN,YAW}
 MOD_ITMX_ISC_COM1_YAW
 MOD_ITMX_ISC_COM2_PIT
 MOD_ITMX_ISC_COM2_YAW
 MOD_ITMX_ISC_COM3_PIT
 MOD_ITMX_ISC_IM_YAW
 MOD_ITMX_ISC_MNOL_HP_{LEN,YAW}
 MOD_ITMX_ISC_MNOL_YAW
 MOD_ITMX_ISC_MN_{PIT,YAW}
 MOD_ITMX_ISC_OL_{PIT,YAW}
 MOD_ITMX_ISC_TM_{LEN,PIT}
 MOD_ITMX_ISC_WD_BP_IM_PIT
 MOD_ITMX_ISC_WD_BP_MN_{LEN,PIT,YAW}
 MOD_ITMX_ISC_WD_BP_TM_LEN
 No value is set for MOD_ITMX_ISC_DRIVEALIGN_*, so nothing is inherited.

To release WD and DK, set the following values:

 K1:VIS-ITMX_TM_WD_OPLEVAC_RMS_MAX: 0 -> 10000
 K1:VIS-ITMX_IM_WD_OSEMAC_RMS_MAX: 0 -> 10000
 K1:VIS-ITMX_MN_WD_OSEMAC_RMS_MAX: 0 -> 10000

The parameters of DITHER were changed to match the original connection as follows

 K1:VIS-SRM_DITHER{P,Y}2EUL_{1,2}_1: {IM,TM}_DTHER_{PIT,YAW}
 Since the combination was connected
 Change K1:VIS-ITMX_DITHER{P,Y}2EUL_{1,2}_1 to 1.0 as well

k1visitmxt:
Model:

  •  Remove the following SHMEM

 K1:VIS-ITMX_IP_COIL_{H1,H2,H3,V1,V2,V3}
 K1:VIS-ITMX_BF_COIL_{H1,H2,H3}
 K1:VIS-ITMXP-VISITMXT_COM2{L,Y}
 K1:VIS-ITMX_GAS_COIL_{F0,F1,F2,F3,BF}
 

  • Add the following SHMEM

 K1:VIS-ITMXP_ISC_MN_OUT

Foton:

 Remove all MOD_*.
 MOD_ITMX_AI_BF_{LEN,PIT,ROL,TRA,VER,YAW}
 MOD_ITMX_AI_IP_{LEN,PIT,ROL,TRA,VER,YAW}

K1visitmxmon:
Model:

Replace with VISMON_MASTER/TYPEAMON as well as ETMY and ETMX.

  •  Delete the following SHMEM

 K1:VIS-ITMX_PREQUA_EXC

Foton:

Rename the original file to _beforePAYLOAD_MASTER and leave the body almost as it was.

SDF:

 CHANS NOT FOUND: SDF RESTORE-LOAD

CHANS NOT INIT: MON(ACCEPT) - CONFIRM

k1modalitmx:

/opt/rtcds/kamioka/k1/target/fb/master
I commented out the next two lines and did killk1modaletmx.
/opt/rtcds/kamioka/k1/chans/daq/K1MODALITMX.ini
/opt/rtcds/kamioka/k1/chans/daq/tpchn/k1modalitmx.par
 

Non-image files attached to this report
Search Help
×

Warning

×