Reports 1-1 of 1 Clear search Modify search
VIS (EY)
kouseki.miyo - 17:40 Tuesday 03 November 2020 (15382) Print this report
Disconnected the cryopayload of ETMY

Ryutaro, Sato, Miyo

Today we was able to successfully detach the cryopayload from the BF in the morning owing to yesterday work so we started preparing to extract the Pre-Isolator(PI) in the afternoon.

  • After the disconnection of the cryopayload we continued to remove the LVDT coils from BF stage to extract the Type-A tower.
  • The cable from the payload crawled along the wire that hangs the payload from the BF so that it wouldn't get in the way when pulling out the tower.
  • Assembled the scaffolding to pull the Pre-Isolator out.
  • We unplugged all the cables from the feedthrough.
  • Turned off all the power of the circuit, includign the function generator for the LVDT reference signal and the stepper motor for the cryopayload.
  • We unplugged a few cables inside the feedthroughs, but there are still a lot of cables left.
  • Tomorrow, we will be able to pull out the PI if we retrieve the remaining cables in the feedthrough and install a jig to fix the wires hanging the F1.

-----
Environment : 22.6°, 44.9% at EYV booth
Photos : Link
Related ticket : Link

Search Help
×