fabian.arellano - 11:40 Monday 14 September 2020 (15027) Print this report
I changed the F1 setpoint and checked the health of BF and F1 fishing rods.

As part of preparation for remedying work I checked the health of BF and F1 fishing rods:

  • BF: it seems completely healthy.
  • F1: I was able to move it down to ~230 um from around 488 um.
  • Temperature: 24.1 degrees.

Therefore, I changed the setpoint in F1 to 230 um. The BS is flat so the change should not have any effect on the IFO.

Long ago I was ony able to move F1 keystone down to around 488 um, but the temperature was higher back then. Now the temperature is 24.1 degrees. 

I took a "GAS setpoints snapshot" for Type-B Gurdian and updated the ALIGNED, MISALIGNED and SAFE SDF values.