Reports 1-1 of 1 Clear search Modify search
MIF (General)
keiko.kokeyama - 23:54 Wednesday 01 April 2020 (13945) Print this report
Power at TMSX IR PDA1 reduced about half

[Akutsu, Miyoki, Kokeyama]

50/50 BS was placed in front of the TMSX IR PD. The power was reduced for a factor of 0.43.

In MEDM, which gain to change, FM1 (name "1.7W") or GAIN (now 3.16) of K1:AOS-TMSX_IR_PDA1??

Comments to this report:
masayuki.nakano - 16:49 Thursday 02 April 2020 (13954) Print this report

I changed the FM1 so that the single arm TRANS got 1 at the FB output when the main laser power is 3.6 W.

Images attached to this comment