taiki.tanaka - 2:26 Wednesday 25 December 2019 (12291) Print this report
installed portable PEMs in REFL
Yokozawa, Washimi, Taiki Tanaka

We installed three PEMs in REFL on 12/15.
- acc TEAC710: K1:PEM-SENSOR_BOOTH_IMC_BNC1
- microphone ACO 7147A/4152: K1:PEM-SENSOR_BOOTH_IMC_BNC2
- acc TEAC706: K1:PEM-SENSOR_BOOTH_IMC_BNC3

Sorry for late report.
Comments to this report:
tatsuki.washimi - 15:58 Friday 27 December 2019 (12333) Print this report

I moved the TEAC706 from REFL box to periscope

Images attached to this comment
tatsuki.washimi - 12:06 Tuesday 03 March 2020 (13292) Print this report

This channel align was wrong!! ch2 and ch3 are inverted!!

correct channels are

  • K1:PEM-SENSOR_BOOTH_IMC_BNC1  -> ACC (TEAC710) in REFL table, Y-direction
  • K1:PEM-SENSOR_BOOTH_IMC_BNC2  -> ACC (TEAC706) on REFL table periscope
  • K1:PEM-SENSOR_BOOTH_IMC_BNC3  -> MIC (ACO 7147A/4152) in REFL booth