Reports 1-1 of 1 Clear search Modify search
DetChar (General)
koya.arai - 16:18 Friday 20 December 2019 (12251) Print this report
Summary of December 19
69,282sec in observing mode
Duty cycle:80.2%

Mean BNS inspiral range:~7kpc
BNS range disturbance(UTC)
5:10
10:45
13:00
20:40
21:30

Loud glitches in K1:CA-_CS_PROC_C00_STRAIN_DBL_DQ(OMPICRON) (UTC)
5:10
6:30
10:30
21:30

Fscan:
K1:CAL-CS_PROC_DARM_DISPLACEMNT_DQ
after 3:30, 1980Hz, 1740Hz, 1680Hz, 1620Hz, 1390Hz, 1370Hz, 1140Hz, 1080Hz, 1060Hz, 890Hz, 790HZ, 770Hz, 540 Hz

K1:CAL-CS_PROC_IMC_FREQUENCY_DQ1
Fluctuation around 1930HZ1515

K1:CAL-CS_PROC_MICH_DISPLACEMENT_DQ
Fluctuation from 1880 to 1940Hz
2:30 Transition at 660Hz

Lockloss
6:30->Large earthquake at Aomori(JST15:25): https://klog.icrr.u-tokyo.ac.jp/osl/?r=12224
8:30->SR3 misalignment(JST17:30): https://klog.icrr.u-tokyo.ac.jp/osl/?r=12239