Reports 1-1 of 1 Clear search Modify search
DetChar (General)
Jishnu.suresh - 11:39 Thursday 19 December 2019 (12219) Print this report
DQ Shift: 18th December 2019

Summary Page – https://gwdet.icrr.u-tokyo.ac.jp/~controls/summary/day/20191218/

Summary of the day

  • Total lock duration was 7761 second (6574 second in observing mode)
  • Fairly low Observing duty cycle for the day: 7.61%
  • Several lock loss during this period.
  • BNS inspiral range was fluctuating around 5kpc.
  • Gltich rate is high (>20) throught out the observing time. 
  • During the lock period 3.5 - 5.5 UTC (not in observing mode),
    •  the BNS range was fairly constant with a mean around 5kpc
K1 HierarchicalVeto
1260576018-1260662418
K1 HierarchicalVeto
1260576018-1260662418
K1 HierarchicalVeto
1260576018-1260662418
K1 HierarchicalVeto (previos day) 1260576018-1260662418
(https://gwdet.icrr.u-tokyo.ac.jp/~controls/summary/day/20191217/detchar/hveto/)
  • Round 1 Winner: K1:IMC-CAV_TRANS_OUT_DQ
  • Round 2 Winner: K1:IMC-CAV_TRANS_OUT_DQ
  • Round 3 Winner: K1:CAL-PCAL_EX_1_PD_TX_V_DQ
  • Round 4 Winner: K1:IMC-CAV_REFL_OUT_DQ
  • Round 5 Winner: K1:PEM_MIC_EYA_BOOTH_EYA_Z_OUT_DQ

Relevant klog entries discussing about the IFO unlock: