VIS (IX)
koki.okutomi - 18:58 Saturday 26 October 2019 (11192) Print this report
ITMX GAS control outputs offloaded by fishing rod

[Takano, Ushiba, Okutomi]

  • DC control outputs in the ITMX GAS loops have been offloaded.
    • Some TEST offset outputs were also disabled which compensated the DAMP control outputs.
  • DAMP output variation with this offloading
    • F1 GAS: ~ +4800 ---> ~0
    • F2 GAS: +20,000 (saturated) ---> ~80
    • F3 GAS: +10,600 ---> ~9220
      • The fishing rod of the F3 GAS seems not operatable at least from the remote interface.
      • But disabling TEST offset could reduce the DC control output.
  • Net operated steps
    • F1 GAS: 0 ---> -2,500
    • F2 GAS: 0 ---> +3,000
    • The UPDATE button in the medm screen doesn't restore the step position in the last operation yet. We need to improve this function.