3:11 - 4:00 FPMI locked (open loop measurement, optical gain evaluation)
4:00 - 4:56 Silent run FPMI + PCal line
4:56 FPMI unlocked
7:41 FPMI unlocked
5:10-8:20 SRM position and noise evaluation. Aligned SRM oplev = (-153.7,-58.9)
- 5:10 SRM optic align value = (P,Y) = (800,800) oplev = (222.3, 313.8) (original)
- 5:30 SRM optic align value = (P,Y) = (800,400) ople v = (220,212)
- 6:10 SRM optic align value = (P,Y) = (800,0)ople v = (217,-126)
- 6:25 SRM optic align value = (P,Y) = (800,-400)ople v = (217,-305)
- 6:45 SRM optic align value = (P,Y) = (400,800)ople v = (212,315)
- 7:01 SRM optic align value = (P,Y) = (0,800)ople v = (45,317)
- 7:16 SRM optic align value = (P,Y) = (-400,800)ople v = (-220,321)
- 7:33 SRM optic align value = (P,Y) = (400,400)ople v = (209,226)
- 8:20 SRM optic align value = (P,Y) = (800,800) (original)
There are not so large difference...