Reports 1-1 of 1 Clear search Modify search
DGS (General)
shoichi.oshino - 14:30 Monday 02 September 2019 (10259) Print this report
Weekly maintenance on Sep. 2, 2019
[Miyakawa, Yamamoto, Oshino]

k1dc0:
We replaced k1dc0 to E5-1650 v4 computer with 32GB memory.

k1tw1:
Old trend data moved from SSD on k1tw1 to HDD on k1nds1.
Comments to this report:
takahiro.yamamoto - 19:08 Tuesday 10 September 2019 (10444) Print this report
Just a progress report.

After someone restarted daqd on k1dc0 at 20:47 on Sep 5th, there is no hang-up until 15:14 on Sep 10th (Maybe Fabian restarted daqd due to update of SR2 model).
Used CPU actually decreases from ~90% to 40%.

########################
[Thu Sep 5 20:47:04 JST 2019 (1567684024)] dc0: Session terminated, killing shell... ...killed.
[Thu Sep 5 20:47:10 JST 2019 (1567684030)] bcst0: New sequence number is 1
[Thu Sep 5 20:47:10 JST 2019 (1567684030)] nds0: New sequence number is 1
[Thu Sep 5 20:47:10 JST 2019 (1567684030)] nds1: New sequence number is 1
[Thu Sep 5 20:47:11 JST 2019 (1567684031)] tw1: Creating K1:DAQ
[Thu Sep 5 20:47:12 JST 2019 (1567684032)] fw0: New sequence number is 1
[Thu Sep 5 20:47:13 JST 2019 (1567684033)] tw0: Creating K1:DAQ
[Thu Sep 5 20:47:14 JST 2019 (1567684034)] fw1: Creating K1:DAQ
[Thu Sep 5 20:47:19 JST 2019 (1567684039)] nds1: 4 129 1251719257 62500000
[Tue Sep 10 15:14:22 JST 2019 (1568096062)] dc0: Session terminated, killing shell... ...killed.
[Tue Sep 10 15:14:28 JST 2019 (1568096068)] bcst0: New sequence number is 1
[Tue Sep 10 15:14:29 JST 2019 (1568096069)] nds0: New sequence number is 1
[Tue Sep 10 15:14:29 JST 2019 (1568096069)] nds1: [Mon Sep 9 23:14:28 2019] connection on fd 50 closed
[Tue Sep 10 15:14:30 JST 2019 (1568096070)] fw0: New sequence number is 1
[Tue Sep 10 15:14:30 JST 2019 (1568096070)] tw1: New sequence number is 1
[Tue Sep 10 15:14:31 JST 2019 (1568096071)] tw0: New sequence number is 1
[Tue Sep 10 15:14:32 JST 2019 (1568096072)] fw1: New sequence number is 1
Search Help
×